This states that a condensing boiler flue should be a minimum of 2.5 metres from a facing wall, fence, building or property boundary. In addition condensing boiler flues should not be sited where the plume is likely to cause a nuisance – which sounds exactly where it has been placed in your case!
Under the boiler flue position regulations, the flue has to be positioned a certain distance from any parts of the home that can be opened up such as windows and doors. How far this is will depend on the size of your boiler but is typically between 30-60cm above, below or to the side of an opening.
Jan 29, 2018· With gas-fired heating contributing about 60% of what is spent in a year on energy bills*, these new regulations should save you money in the years to come. All boilers installed from April 2018 will need an ErP efficiency rating of 92% or higher. Roughly a third of the boilers on the market today fall short of this standard.
In addition to the boiler unit, an oil-fired boiler requires a feed water supply, a boiler loop/heat delivery system (e.g., hydronic radiators), fuel storage, fuel supply equipment, and a temperature control system.
Aug 03, 2018· The regulations differ for most boiler models depending on their size, but the typical guide is that the flue needs to be at least 30cm away from an opening, such as a window, if it is to be placed above or to the side of said opening. Boilers on the larger side need to have their flues positioned up to 60cm away from those openings.
Each boiler must have a minimum efficiency of 86% for gas and 85% for oil. The replacement of a gas boiler will probably have to be a condensing boiler unless there is sufficient reason why one cannot be installed. An assessment is carried out by a registered installer on the type of boiler you will be required to have. The assessment is described in the Ministry of Housing, Communities and Local Government …
The position of flue terminals (i.e. where the flue discharges through a wall or roof) is strictly regulated. Oil fired boiler flues must not be terminated beneath windows or where higher parts of the building will affect the draw of the flue or chimney. Condensing flue boilers emit large plumes of water vapour.
Code of practice for oil firing. Installations of 45 kW and above output capacity for space heating, hot water and steam supply services. BS 5440-1:2008. Installation and maintenance of flues and
Safe Standing. The oil tank must have a base that is suitable throughout the year. The base must be adequate for the weight of the tank, non-combustible, imperforte and level. It should be constructed of concrete, paving stones or stonework and extend at least 300mm beyond all sides of the tank.
Although Building Regulations permit both types of boiler to be located in domestic garages, we recommend that only balanced flue boilers are used in those areas. Most modern boilers use a pressure jet burner; although some vaporising burner machines are still available on the market, they may only be fitted into a limited number of locations.
The whole point of a boiler flue is to prevent potentially harmful gases from being breathed in and for that reason boiler flue regulations are in place. These regulations ensure the flue isn’t too close to windows and doors of the property it’s fitted onto and neighbouring buildings. So, where can a flue be fitted?